Heater/Blower fan does not work
Diagnostic procedure 1. Check fuse 3 and that it is live.
2. Unplug the 8-pin connector from the rear of the control panel and check whether pin 2 of the connector is live.
3. Check the wiring between pin 2 of the control panel and fuse 3 for continuity/shorting.
4. Unplug the fan's connector and check the voltage as shown below:
5. Check the voltage on the following pins at the rear of the control panel's 8-pin connector. Readings should be taken with the fan connector unplugged and the control panel connector plugged in.
6. Check the leads for shorting/continuity if correct readings were obtained when carrying out point 5 but not when carrying out point 4.